This is an economical air purifier that compactly integrates an air purifier and a regulator (pressure reducing valve).
Pressure adjustment function only
Purpose
It can be used for applications where the compressed air supplied from the air compressor is reduced and adjusted to the desired pressure.
explanation
-NAR and AR types are self-relief types, so if the pressure exceeds 5% of the set pressure, it will automatically release to the atmosphere and adjust the secondary pressure.
・The NAR type is a compact type with a built-in pressure gauge.
- Pressure adjustment can be easily done with one hand, and the lock can be operated with one push.
Specification
format | Connection diameter | Air flow rate [L/min] | Maximum pressure on the primary side [MPa] | Secondary pressure adjustment range [MPa] | Relief valve operating pressure [MPa] | Maximum usable fluid temperature [℃] | remarks |
---|---|---|---|---|---|---|---|
NAR-202 | Rc 1/4 | 2100 | 1.0 | 0.05~0.85 | 0.005 | 60 | -- |
NAR-203 | RC 3/8 | 2800 | 1.0 | 0.05~0.85 | 0.005 | 60 | -- |
NAR-204 | Rc 1/2 | 5000 | 1.0 | 0.05~0.85 | 0.005 | 60 | -- |
AR-206BG | Rc 3/4 | 10000 | 2.06 | 0.07~0.83 | -- | 65 | The air flow rate is when the primary side pressure is 0.7MPa{7kgf/cm2}, the secondary side set pressure is 0.5MPa{5kgf/cm2}, and the pressure drop is 0.08MPa{0.8kgf/cm2}. |
AR-208BG | Rc 1 | 10000 | 2.06 | 0.07~0.83 | -- | 65 | The air flow rate is when the primary side pressure is 0.7MPa{7kgf/cm2}, the secondary side set pressure is 0.5MPa{5kgf/cm2}, and the pressure drop is 0.08MPa{0.8kgf/cm2}. |
AR-302CG | Rc 1/4 | 350 | 2.06 | 0.04~0.83 | -- | 65 | The air flow rate is when the primary side pressure is 0.7MPa{7kgf/cm2}, the secondary side set pressure is 0.5MPa{5kgf/cm2}, and the pressure drop is 0.08MPa{0.8kgf/cm2}. |